Analisis Hubungan Persentase Ketidakseimbangan Beban terhadap Rugi Daya pada Transformator Distribusi di PT PLN (Persero) ULP Binjai Timur

Authors

  • Alexius Victor Purba Universitas Pembangunan Panca Budi
  • Haris Gunawan Universitas Pembangunan Panca Budi
  • Dino Erivianto Universitas Pembangunan Panca Budi

DOI:

https://doi.org/10.55606/jutiti.v6i1.6687

Keywords:

Load Imbalance, Power Distribution, Power Losses, Quantitative Approach, Transformer

Abstract

The distribution transformer is one of the most important components in the electrical power distribution system. Distribution transformers often experience load imbalance issues. One previous study indicated that load imbalance can reach 25.6%, contributing to an increase in power losses. This study aims to analyze the relationship between the percentage of load imbalance and the power losses that occur at PT. PLN (Persero) ULP Binjai Timur. This research was conducted using a quantitative approach by calculating the percentage of load imbalance and the resulting power losses. Data were collected through direct observation, voltage and current measurements, followed by calculations and analysis. The results of the study show that the higher percentage of load imbalance occurred at night, with 12.96%, while during the day it was 10.03%. The power losses were higher at night, amounting to 853.3 watts, while during the day it was 4,386.3 watts. Therefore, it can be concluded that the higher the percentage of load imbalance, the higher the power losses that occur.

Downloads

Download data is not yet available.

References

Afrianda, R., Samsurizal, S., & Nurul, A. A. (2021). Pengaruh ketidakseimbangan beban terhadap efesiensi transformator distribusi studi gardu PT PLN (Persero) Area Bekasi. Sutet, 10(1), 29–38. https://doi.org/10.33322/sutet.v10i1.1277

Aini, Z., Mutari, E., Liliana, L., & Candra, O. (2021). Analysis of imbalance loads and losses based on the largest loading by 3 units of 3-phase distribution transformer. JTEV (Jurnal Teknik Elektro dan Vokasional), 7(1), 69–75. https://doi.org/10.24036/jtev.v7i1.111965

Anisah, S. (2018). Analisis perbaikan tegangan ujung pada jaringan tegangan menengah 20 kV Express Trienggadeng daerah kerja PT PLN (Persero) Area Sigli Rayon Meureudu dengan simulasi E-Tap. Journal of Electrical and System Control Engineering, 2(1), 2–7. https://doi.org/10.31289/jesce.v2i1.1916

Ardiansyah, M. R., & Erivianto, D. (n.d.). Analysis of drop voltage in low voltage network (JTR) 380/220 volt distribution substation of PT PLN (Persero) ULP Tanah Jawa. pp. 469–480.

Frangino, S. S. M., & Gatot, B. (2024). Analisa pengaruh ketidakseimbangan beban terhadap arus netral dan losses pada trafo distribusi di EDTL, E.P. Jurnal Ilmiah Research Student, 1(3), 90–103.

Ginting, R. T. (2022). Analisis ketidakseimbangan beban jaringan distribusi tegangan rendah menggunakan ETAP. Sain, Energi, Teknologi & Industri, 6(2), 81–89. https://doi.org/10.31849/sainetin.v6i2.9734

Jatmiko, H. B., Trihasto, A., & Pravitasari, D. (2024). Evaluasi ketidakseimbangan beban terhadap arus netral pada transformator di gardu induk 150 kV Secang. RELE (Rekayasa Elektrikal dan Energi): Jurnal Teknik Elektro, 1–8. https://doi.org/10.30596/rele.v7i1.20350

Muliadi, M., Syukri, S., Asyadi, T. M., & Salim, A. (2022). Analisa pengaruh ketidakseimbangan beban pada trafo distribusi penyulang Mibo Rayon Merduati. Aceh Journal of Electrical, 2(2), 7–12.

Novfowan, A. D. M., Mieftah, M., & Kusuma, W. (2021). Alternatif penanganan losses akibat ketidakseimbangan beban pada trafo distribusi. Jurnal Teknik Ilmu dan Aplikasi, 9(1), 83–90. https://doi.org/10.33795/jtia.v9i1.17

Ramadhan, R., Lesmana, D., & Tharo, Z. (2024). Penurunan drop tegangan penyulang 20 kV dengan metode pecah beban. Power Elektronik: Jurnal Orang Elektro, 13(2), 288–292. https://doi.org/10.30591/polektro.v13i2.6849

Reza, I., & Gunawan, A. (2021). Pengaruh ketidakseimbangan beban terhadap arus netral dan rugi-rugi pada transformator 3 fasa 20 kV/400 V di PT. SGMW Motor Indonesia. Jurnal Sains & Teknologi, 11(3), 109–116.

Rohmat, K., & Riyadi, M. A. (2023). Analisis ketidakseimbangan beban transformator distribusi. Jurnal, 4, 186–192. https://doi.org/10.14710/transmisi.25.4.186-192

Ruliyanto, R. (2020). Pengaruh ketidakseimbangan beban terhadap arus netral dan arus ground pada trafo 1 dan trafo 2 pada beban puncak sesaat. Jurnal Ilmiah Giga, 23(1), 27–35. https://doi.org/10.47313/jig.v23i1.867

Sains, J. (2022). SAINTEK+ Vol. 1 No. 2 Desember 2022, 106–123. Sainteknologi, 1(2), 106–123.

Sam, J. F., & Gunawan, H. (2025). Analysis and simulation of load unbalance of distribution transformer feeder LK.10 in ULP Medan City. Jurnal, 5(2). https://doi.org/10.56495/hs.v5i2.1239

Satrio, A., Slamet, P., & Widagdo, R. S. (2023). Analisa keandalan transformator distribusi menggunakan Weibull distribution di wilayah ULP Rungkut Kota Surabaya. Jurnal FORTECH, 2(2), 51–56. https://doi.org/10.56795/fortech.v2i2.203

Siagian, A. Z., Zulkarnain, Z., Dalimunthe, M. E., & Tharo, Z. (2023). Analisis kehandalan sistem konfigurasi jaringan penyulang 20 kV di PT. PLN (Persero) ULP Pakam Kota berbasis Matlab. Jurnal Rekayasa Elektro Sriwijaya, 5(1), 18–31. https://doi.org/10.36706/jres.v5i1.89

Siregar, R. S., & Harahap, R. (n.d.). Perhitungan arus netral, rugi-rugi, dan efisiensi transformator distribusi 3 fasa 20 kV/400 V di PT PLN (Persero) Rayon Medan Timur akibat ketidakseimbangan beban.

Sutama, I. W., & Sari, I. A. L. N. (2023). Analisis ketidakseimbangan beban pada gardu distribusi KA 0251 penyulang Gelogor Carik. Jurnal Ilmiah Telsinas Elektro, Sipil dan Teknik Informasi, 6(2), 209–218. https://doi.org/10.38043/telsinas.v6i2.4893

Sya’roni, Z., & Rijanto, T. (2019). Analisis ketidakseimbangan beban transformator distribusi 20 kV dan solusinya pada jaringan tegangan rendah. Teknik Elektro, 8(1), 173–180.

Tonda, H., Parsa, M., Crispinus, D., & Tamal, P. (2025). Pengaruh ketidakseimbangan beban terhadap arus netral trafo pada gardu distribusi di PT PLN (Persero) ULP Larantuka. Jurnal Teknologi, 19(1), 15–23.

Unifibercable. (n.d.). A3CS / AAACS Cable Indonesia – Overhead Insulated Cable. Retrieved from https://unifibercable.com/products/overhead-insulated-cable/a3cs-aaacs-cable-indonesia.html

Yusiran, Y., & Hasanudin, H. (2025). Analisis pengaruh ketidakseimbangan beban terhadap rugi-rugi daya dan efisiensi transformator step down 20 kV/400 V. Jurnal Penelitian Inovatif, 5(3), 2113–2120. https://doi.org/10.54082/jupin.1675

Zebua, O., Komalasari, E., Alam, S., & Aldiansyah, A. (2021). Rancang bangun alat monitoring ketidakseimbangan beban transformator distribusi berbasis Internet of Things. Electrician, 15(2), 146–152. https://doi.org/10.23960/elc.v15n2.2203

Downloads

Published

2026-01-21

How to Cite

Alexius Victor Purba, Haris Gunawan, & Dino Erivianto. (2026). Analisis Hubungan Persentase Ketidakseimbangan Beban terhadap Rugi Daya pada Transformator Distribusi di PT PLN (Persero) ULP Binjai Timur. Jurnal Teknik Informatika Dan Teknologi Informasi, 6(1), 142–154. https://doi.org/10.55606/jutiti.v6i1.6687